Sign In | Join Free | My entremaqueros.com
China SHENZHEN WEIMING PHOTOELECTRIC CO.,LTD. logo
SHENZHEN WEIMING PHOTOELECTRIC CO.,LTD.
SHENZHEN WEIMING PHOTOELECTRIC CO.,LTD.
Verified Supplier

1 Years

Home > X Ray Image Intensifier >

Canon X Ray Image Intensifier With Variable FOV 4/2-Inch Modes High Contrast For PCB Testing

SHENZHEN WEIMING PHOTOELECTRIC CO.,LTD.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Canon X Ray Image Intensifier With Variable FOV 4/2-Inch Modes High Contrast For PCB Testing

Brand Name : Canon

Model Number : E5877J-P1K

Certification : CE, FDA

Place of Origin : JAPAN

MOQ : 1

Payment Terms : T/T

Nominal Entrance Field Size : typ. 100 mm

Output Image Diameter : 20±1 mm

DC Power Supply Input Voltage : 100 to 240 Vac 30VA

Contact Now

Canon/Toshiba Image Intensifier E5877J-P1K
Product Overview
The X-ray Image Intensifier E5877J-P1K is a high-performance industrial imaging solution engineered to deliver clear, detailed X-ray images. Boasting extremely high resolution and effective soft X-ray penetration, it is ideal for non-destructive inspection applications in electronics, automotive, aerospace and other industries. This lightweight, compact device enhances imaging efficiency and precision, ensuring reliable, accurate results.
Canon X Ray Image Intensifier With Variable FOV 4/2-Inch Modes High Contrast For PCB Testing
Key Features
  • The output screen's anti-reflective coating improves image quality
  • Dual operation modes (N mode and M mode) cater to diverse imaging requirements
  • Quick setup with preheating time under 3 minutes
  • Adherence to international safety standards ensures reliable, safe operation
  • Achieves very high resolution up to 110 Lp/cm in M mode for detailed imaging
  • Compact design with an overall length of 226 mm and maximum diameter of 164 mm
  • Lightweight, weighing approximately 8.0 kg for easy integration and handling
  • CsI direct deposit input screen reduces X-ray scatter and improves detection efficiency
Technical Specifications
Mechanical Specifications
  • Overall Length: 226±3 mm
  • Maximum Diameter: 164±3 mm
  • Nominal Entrance Field Size: typ. 100 mm
  • Output Image Diameter: 20±1 mm
  • Weight: approx. 8.0 kg
Electrical Specifications
  • Anode Voltage: 25 to 30 kV (N mode), 25 to 30 kV (M mode)
  • G3 Electrode Voltage: 1.5 to 3.5 kV (N mode), 9.0 to 12.0 kV (M mode)
  • G2 Electrode Voltage: 350 to 750 V (N mode), 150 to 550 V (M mode)
  • G1 Electrode Voltage: 50 to 250 V (N mode), 150 to 350 V (M mode)
  • Photocathode Voltage: 0 V
Power Supply Specifications
  • DC Power Supply Input Voltage: 100 to 240 Vac 30VA
  • DC Power Supply Output Voltage: 24±1 Vdc
  • DC Power Supply Output Current: 400 mA max.
  • Weight: approx. 1 kg
Environmental Specifications
  • Operating Temperature: 5°C to 40°C
  • Storage Temperature: -15°C to 45°C
  • Operating Humidity: 30% to 85% RH (non-condensing)
  • Storage Humidity: 10% to 90% RH (non-condensing)
  • Operating Pressure: 70 to 106 kPa
  • Storage Pressure: 50 to 106 kPa
Performance Specifications
  • Central Resolution: 77 Lp/cm (N mode), 110 Lp/cm (M mode)
  • Conversion Factor (Gx): 90 cd/m2 (typ.) for 10 μGy/s (N mode), 90 cd/m2 (typ.) for 1 mR/s (M mode)
  • Contrast Ratio: 22:1 (10% area) (N mode)
Safety and Handling Specifications
  • Maximum Fluoroscopic X-ray Tube Voltage: 125 kVp
  • Maximum Input Dose Rate: Continuous 4.37*10^-4 Gy/min [50 mR/min], Pulsed 8.73*10^-3 Gy/min [1 R/min]
  • Minimum Distance Between Focal Spot and Entrance Plane: 73 cm

Product Tags:

Canon X Ray Image Intensifier

      

High Contrast X ray Image Intensifier

      

PCB Testing Xray Image Intensifier

      
 Canon X Ray Image Intensifier With Variable FOV 4/2-Inch Modes High Contrast For PCB Testing Manufactures

Canon X Ray Image Intensifier With Variable FOV 4/2-Inch Modes High Contrast For PCB Testing Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: SHENZHEN WEIMING PHOTOELECTRIC CO.,LTD.
*Subject:
*Message:
Characters Remaining: (0/3000)